The National Health Commission has issued the “Technical Requirements for the Hygienic Safety Evaluation of Low-Temperature Disinfectants.”
Jan 25,2021
To the Health Commissions of all provinces, autonomous regions, municipalities directly under the central government, and the Xinjiang Production and Construction Corps, as well as to the Chinese Center for Disease Control and Prevention:
Recently, multiple regions across China have reported positive nucleic acid test results for the novel coronavirus on the outer packaging of cold-chain products, and outbreaks of COVID‑19 linked to such items have occurred from time to time. To address the urgent need for nationwide epidemic prevention and control and to ensure the effectiveness of low-temperature disinfection, the following matters are hereby notified:
Low‑temperature disinfectants used for surface disinfection of cryogenically frozen items shall, upon market release, undergo a hygiene and safety assessment in accordance with the “Regulations on the Hygiene and Safety Evaluation of Disinfection Products” and be filed accordingly. Only low‑temperature disinfectants that pass this hygiene and safety evaluation may be marketed and sold. The hygiene and safety evaluation shall cover the product label, instructions for use, product formulation, test report (with test items as specified in the annex and including conclusions), enterprise standards or quality standards, the hygienic license of the domestic manufacturer, and, for imported products, documentation certifying that the country or region of manufacture permits production and sale, together with the customs declaration.
Domestic manufacturers seeking emergency market authorization for low‑temperature disinfectants must obtain a hygiene license for disinfectant product manufacturing. Upon emergency approval, the responsible entity shall promptly submit the following compliant registration materials to the local disinfectant product filing authority: product labels, instructions for use, product formulation, enterprise standards or quality standards, and a product quality and safety commitment (including test reports demonstrating compliance with specifications for active ingredient content, pH, microbial kill efficacy, field trials, and low‑temperature testing). For comparable imported low‑temperature disinfectants, in addition to the aforementioned documents, the responsible entity in China must also provide the local disinfectant product filing authority with proof of authorization to manufacture and sell the product in its country or region of origin, along with the customs declaration form. Furthermore, exported low‑temperature disinfectants must comply with the relevant requirements of the importing country or region.
While emergency‑approved low‑temperature disinfectants are being marketed and used, the responsible product entity shall conduct testing in accordance with the inspection items specified in the Technical Requirements for the Hygienic Safety Evaluation of Low‑Temperature Disinfectants and complete the required filing as stipulated in the Regulations on the Hygienic Safety Evaluation of Disinfection Products. As of June 1, 2021, any product‑responsible entity that has not yet completed the requisite testing and filing must immediately cease the production and sale of such emergency‑approved low‑temperature disinfectants. Entities that nevertheless wish to continue production and sales must follow the standard procedures; otherwise, they will be subject to strict enforcement in accordance with the Law on the Prevention and Control of Infectious Diseases, the Measures for the Administration of Disinfection, and other relevant regulations.
Attachment: Technical Requirements for the Hygienic and Safety Evaluation of Low-Temperature Disinfectants
General Office of the National Health Commission
December 31, 2020
Technical Requirements for the Hygienic and Safety Evaluation of Low-Temperature Disinfectants
The testing items for low‑temperature disinfectants shall be conducted in accordance with the requirements for hard‑surface disinfectants set forth in the “Technical Requirements for the Hygienic Safety Evaluation of Disinfection Products” (WS 628‑2018), with the addition of a low‑temperature test. The test methods and evaluation criteria may refer to relevant standards and specifications, including the “Disinfection Technical Specifications” (2002 edition), the “Laboratory Methods for Evaluating the Germicidal Efficacy of Disinfectants” (GB/T 38502‑2020), and the “Procedures and Methods for the Safety and Toxicological Evaluation of Disinfectants” (GB/T 38496‑2020). Microbial kill tests shall be performed under the specific low‑temperature conditions specified in the product’s instructions. Because low‑temperature disinfectants are intended for use at low temperatures, their testing items and evaluation methods differ from those of conventional hard‑surface disinfectants. The specific technical requirements are as follows:
I. Laboratory Microbial Inactivation Test
Laboratory tests shall be conducted using the carrier method.
Prior to testing, place the low-temperature disinfectant (application solution) under the specified low-temperature conditions indicated in the product instructions, and use a thermometer to measure its temperature. Only after the designated low temperature has been reached may the test procedures be carried out.
After the inoculated carrier has dried, it shall be stored at the specified low temperature indicated in the product instructions for at least 30 minutes.
During experimental procedures, ensure that the temperature at which the low-temperature disinfectant and the bacterial test strips are exposed remains within the specified low-temperature range.
II. Field Trials
Select the appropriate test site in accordance with the application scenarios specified in the product’s standard instruction manual, and use the disinfection equipment in conjunction with it. Conduct simulated field trials using carriers inoculated with indicator microorganisms. Typically, cloth swabs are chosen as carriers; however, when employing aerosol or ultra‑low‑volume spraying methods, carriers with adsorptive properties—such as cloth swabs or filter paper—are not suitable. Instead, metal or glass slides may be used.
Staphylococcus aureus (ATCC 6538) and Escherichia coli (8099), which exhibit relatively high resistance to the novel coronavirus, are selected as indicator microorganisms. If specific requirements apply, the type I poliovirus (PV‑I) vaccine strain may also be chosen as the indicator microorganism.
Place the carrier inoculated with the indicator microorganism in the on-site low-temperature environment for at least 30 minutes, ensuring that the indicator microorganisms have reached the specified low temperature before proceeding with the field experiment. During testing, position the carrier inoculated with the indicator microorganism at the most difficult-to-disinfect location.
III. Low-Temperature Test
At the minimum applicable temperature specified in the low-temperature disinfectant’s instructions, test whether the disinfectant remains in a liquid state. Take 5 mL of the low-temperature disinfectant (the working solution) and leave it at the corresponding low temperature overnight (>8 hours), then observe and record its physical characteristics. If the disinfectant remains liquid, with no precipitation or crystallization, it is deemed compliant.
Source: China Detergent Industry Information Network